Home > Products > PA (34-47-64-108)*SE

PA2 034 - PA2 047 - PA2 064 - PA2 084 - PA2 108

PA2 034 - PA2 047 - PA2 064 - PA2 084 - PA2 108

PRODUCT NAME: PA2 034 - PA2 047 - PA2 064 - PA2 084 - PA2 108







TECNICAL DATA:



SPECIFICATIONS AND TECHNICAL DATA

TYPE

 


 


PA2 34

PA2 47

PA2 64

PA2 84

PA2 108

Displacement

Vg.

cm3/n

34.60

47.39

64.08

84.38

107.70

Max operating pressure

P1

bar

450

450

450

400

350

Max peak pressure (< 0.1 s)

P3

500

500

500

450

400

Max intermittent speed (P < 30 bar)

n3

r.p.m.

3000

2600

2500

2400

2200

Max continuous speed (< P1)

n1

2400

2100

2000

1900

1700

Min intermittent speed (< P1 x 0.5) (max 30 s)

n4

300

Suction pressure (absolute)

P

bar

0.7 -f 1.5

Operating viscosity range

V

cST

9^-75

Optimal viscosity range

V

15^-46

Start up max viscosity

V

1000

Fluid temperature °C (t)

t

°C

-25 -f- 80



 

DIMENSIONS

 

Medidas FOX 34-108

>Medidas FOX 34-108 (2)

 

SPECIFICATIONS AND TECHNICAL DATA

 


OUTLET

INLET

WEIGHT

TYPE

CODICE

A

B

C

D

E

F

G

H

L

M

N

P

Q

Kgrs

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

PA2 34

011010341R/L

109

113

220

308

107

157

107.5

102

95

46

3/4" G

1"G

45

10.5

PA2 47

011010471R/L

109

113

220

308

107

157

107.5

102

95

46

3/4" G

1"G

45

10.5

PA2 64

011010641R/L

118

128

240

328

118

173

107.5

110

110

60

1"G

1" 14

51

13.5

PA2 84

011010841R/L

118

128

240

328

118

173

107.5

110

110

60

1"G

1" 14

51

13.5

PA2 108

011011081R/L

118

128

240

328

118

173

107.5

110

110

60

1"G

1" 14

51

13.5

 



 

INSTALLATION INSTRUCTIONS


Montaje FOX 34-108

Failing to observe this rule may cause damages to the pump.

BEFORE STARTING UP MAKE SURE THAT THE PUMP 1SFILLED WITH OIL, EITHER BYBLEEDING THE AIR THROUGH THE DRAINAGE HOLE OR BY FILUNG THE PUMP UP PREVIQUSLY.

DIRECTION OF ROTATION/CHANGE OF ROTATION

Montaje FOX 34-108 (2)

 

Outlet

Choosing the direction of rotation:

CLOCKWISE ROTATING PUMP
(ANTICLOCKWISE ROTATING P.T.O.)

 

 

 

To change the direction ofrotation remove the 4 screws

and, keeping the distributor body cióse to the pump,

roíate itby 180°. Tighten the 4 screws at 80 ±5 Nm.

ARROW+ NOTCH = DIRECTION OFROTATION

Montaje FOX 34-108 (3)

 

 

WARNING: during this operation the distributor body

must not move away from the pump body more than

2 mm.


 

 

 

 

 

ANTICLOCK WISE ROTATING PUMP
(CLOCKWISE ROTATING P.T.O.)



If you wish to order this product, click Here

INDUSTRIAS J.CORTÉS, s.l. c/ Alaun 24, Polígono PLA-ZA, 50197, Zaragoza.
tel.: +34 976 503 578, fax.: +34 976 503 779
SPAIN
Developed by iA Soft